The grate is representative of the entire design line.
![Image Slotted grating Image Slotted grating](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/2c/a0/2ca00f69-5f0c-4f9e-8c37-b5743db8601b/self_stegrost_neu.jpg__1300x0_q90_subsampling-2.jpg)
ANRIN SELF structural elements made of resin concrete
The ANRIN SELF-150 channels are exclusively used in residential construction. The main applications are driveways, courtyards and terraces.
SELF-150 channel product specifications | |
---|---|
Material | polymer concrete |
Length | 50 / 100 cm |
Width | 20 cm |
Height | 8.0 cm. 15.0 cm cm |
Weight | 9 - 17.8 kg |
Nominal width | 150 |
Joint formation | UNILINK®- Joint |
Clasp | Screw fastening |
Load capacity | galvanised slotted grating cl. A15, mesh grating cl. B125 , cast grating cl. C250 |
ANRIN UNILINK®-Joint
![Image <p>ANRIN UNILINK<sup>®</sup>-Joint</p> Image <p>ANRIN UNILINK<sup>®</sup>-Joint</p>](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/46/20/4620029b-7a1d-44f5-91f4-52345d6d10f4/unilink_fuge.jpg__0x150_q90_subsampling-2.jpg)
![Image 2 <p>ANRIN UNILINK<sup>®</sup>-Joint</p> Image 2 <p>ANRIN UNILINK<sup>®</sup>-Joint</p>](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/aa/ec/aaece3e1-9b34-4af0-91e0-317ec30a500c/unilink_fuge.jpg__0x150_q90_subsampling-2.jpg)
The optimised UNILINK® joint system eliminates the traditional differentiation between the beginning and end of the channel. Elements of an equal installation height can be joined in any arbitrary direction. The symmetrically divided half-joints enable the optional sealing of the splicing. Vertically aligned grooves and tongues support an efficient installation: In the process, the installation alignment can be chosen arbitrarily!
The flexibility in the design and installation phases enters a new dimension with the UNILINK® joint!
ANRIN Screw fastening
![Image ANRIN Screw fastening Image ANRIN Screw fastening](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/b3/65/b36535d2-5c33-4547-93b5-8cd0aeccad9b/schraub-verschluss.jpg__800x0_q90_subsampling-2.jpg)
Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.
ANRIN fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.
Accessorie for SELF-150
![Image Channel body Image Channel body](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/c4/9d/c49d5d44-e976-4a23-afb9-eb27e8c6a184/self_150_50cm.png__800x0_subsampling-2.png)
Channel body
SELF-150
![Image End cap Image End cap](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/16/cf/16cfdc84-3c14-42e2-8bab-b5db533c54cc/self_150_stirnwand_07317100.jpg__800x0_q90_subsampling-2.jpg)
End cap
SELF-150
![Image End cap Image End cap](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/6d/b3/6db3a0c9-cf00-4d46-9d89-084b9befa04e/self_150_stirnwand_mit_rohrstutzen_07318100.png__800x0_subsampling-2.png)
End cap
with DA / OD 160 pipe socket
SELF-150
![Image Sump unit Image Sump unit](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/9f/c2/9fc270e8-2ef9-4375-b0d0-c94b52685a1e/self_150_einlaufkasten_07316001.png__800x0_subsampling-2.png)
Sump unit
SELF-150
SELF installation instructions
With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.
Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.
The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.
Constructions are to be re-created on a project-specific basis.
![Image 1 SELF-150 Installation guide Image 1 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/98/da/98da91ee-6007-4940-a693-cb1c5ece0386/montageschritt_1_lay4.jpg__800x0_q90_subsampling-2.jpg)
1.
Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.
![Image 2 SELF-150 Installation guide Image 2 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/80/a3/80a369d9-387d-4aa5-ac56-cfcc68dbfe0e/montageschritt_2_lay4.jpg__800x0_q90_subsampling-2.jpg)
2.
Connect pipe connections to the pipeline.
![Image 3 SELF-150 Installation guide Image 3 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/0c/0c/0c0cef2f-6b8f-4fff-b826-815247187b2d/montageschritt_3_lay4.jpg__800x0_q90_subsampling-2.jpg)
3.
Place channel elements and sump unit on the concrete pad. Align components so that they are level.
![Image 4 SELF-150 Installation guide Image 4 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/e6/f1/e6f1790b-54b8-4ae3-a6cb-a7e12f4f425a/montageschritt_4_lay4.jpg__800x0_q90_subsampling-2.jpg)
4.
Position end caps.
![Image 5 SELF-150 Installation guide Image 5 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/a0/52/a052bba8-8a97-46f2-b1f6-36c502a1e772/montageschritt_5_lay4.jpg__800x0_q90_subsampling-2.jpg)
5.
Complete the series and ensure the level alignment of the components.
![Image 6 SELF-150 Installation guide Image 6 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/10/c4/10c45d5e-f4a2-4b1e-91e8-a2ddb295ac67/montageschritt_6_lay4.jpg__800x0_q90_subsampling-2.jpg)
6.
Backfill the concrete pad.
![Image 7 SELF-150 Installation guide Image 7 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/5e/a3/5ea35503-498c-47a6-b336-a72569d0d466/montageschritt_7_lay4.jpg__800x0_q90_subsampling-2.jpg)
7.
Lay the paving.
![Image 8 SELF-150 Installation guide Image 8 SELF-150 Installation guide](https://anrinwebsite-live-e2105a4f1efd46c78448d-fdc6f83.divio-media.net/filer_public_thumbnails/filer_public/54/09/540985e0-b270-413f-b866-909ecd08e18e/montageschritt_8_lay3.jpg__800x0_q90_subsampling-2.jpg)
8.
The surface should be 2 to 5 mm higher than the cover grating.
Instructions and Regulations
Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.
For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas“
DIN 19580 „Drainage channels for vehicular and pedestrian areas“
RStO „Guidelines for the standardisation of the superstructure of vehicular areas“
DIN EN 206-1 „Concrete. Specification, performance, production and conformity“
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1“
Das ausgewählte Rost ist nicht in der Belastungsklasse verfügbar. Möchten Sie zur Rost-Übersicht für die gewünschte Belastungsklasse?
Das ausgewählte Rost ist nicht in der Nennweite verfügbar. Möchten Sie zur Rost-Übersicht für die gewünschte Nennweite?
Das ausgewählte Rost ist nicht mit diesem Material verfügbar. Möchten Sie zur Rost-Übersicht mit dem gewünschten Material?
Das ausgewählte Rost ist nicht mit dem gewünschten Filter verfügbar. Möchten Sie zur Rost-Übersicht?