Slotted top

with maintenance opening (left)

Material: galvanised steel
Length: 100 cm
Load class: A15, B125

Matching channel body

SELF-100 channel
Load class:
A15, B125
Image channel

ANRIN Slotted top channel

A drainage system for customers who place greater value on aesthetic solutions. It consists of the actual resin concrete channel body and a slotted top made of galvanised or stainless steel. This is formed by 2 angled metal plates. The shaft ends in a narrow slot. The metal plates are covered with panels or paving during installation so that only the slot is visible at the surface. This channel system is primarily used decoratively in city settings for prestigious urban development and is suitable for traffic loads of up to D400*.

SELF-100 channel Product specifications
Material polymer concrete
Length 50 und 100 cm
Width 12 cm
Height 10 cm
Weight 4.5 - 8.0 kg
Nominal width 100
Clasp Rast-Verschluss
Load capacity Stahl-Stegrost Kl. A15, verzinkter Maschenrost Kl. B125, Edelstahl-Längsprofilrost Kl. B125, Guss Stegrost Kl. B125, Kunststoffrost Kl. B125

Channel dimensions for SELF-100

Image Gutter size for SELF-100 channel

ANRIN Snap-in fastening

Image ANRIN Snap-in fastening

Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.

ANRIN Snap-in fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.

Accessorie for SELF-100

Image End cap

End cap

SELF-100

Image End cap

End cap

with DA / OD 110 pipe socket

SELF-100

Image Foul air trap

Foul air trap

DA/OD 110

SELF-100

Image Sump unit

Sump unit

  

SELF-100

Accessories dimensions for SELF-100 sump unit

Image Accessories dimensions for SELF-100 sump unit

SELF installation instructions

With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.

Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.


The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.

Constructions are to be re-created on a project-specific basis.

Image 1 SELF-100 Installation guide

1.

Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.

Image 2 SELF-100 Installation guide

2.

Connect pipe connections to the pipeline.

Image 3 SELF-100 Installation guide

3.

Place channel elements and sump unit on the concrete pad. Align components so that they are level.

Image 4 SELF-100 Installation guide

4.

Position end caps.

Image 5 SELF-100 Installation guide

5.

Complete the series and ensure the level alignment of the components.

Image 6 SELF-100 Installation guide

6.

Backfill the concrete pad.

Image 7 SELF-100 Installation guide

7.

Lay the paving.

Image 8 SELF-100 Installation guide

8.

The surface should be 2 to 5 mm higher than the cover grating.

Instructions and Regulations

Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.


For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas
DIN 19580 „Drainage channels for vehicular and pedestrian areas
RStO „Guidelines for the standardisation of the superstructure of vehicular areas
DIN EN 206-1 „Concrete. Specification, performance, production and conformity
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1

Back to overview
DESELECT ALL FILTERS
Load capacity A15

A15
(Test force 15kN)

Load capacity B125

B125
(Test force 125kN)

Load capacity C250

C250
(Test force 250kN)

Load capacity D400*

D400*
(Test force 400kN)

Load capacity E600*

E600*
(Test force 600kN)

Load capacity F900*

F900*
(Test force 900kN)

* Exception: Cross-road drainage of busy roads SW = slot width / MW = mesh width

Nominal width 100

100
Nominal width

Nominal width 150

150
Nominal width

Nominal width 200

200
Nominal width

Nominal width 300

300
Nominal width

Stainless steel
Cast-iron
Synthetic
Back to overview